ZPD-10数显纸张腻滑度测定仪(无汞)应用解释书
一、型号含义及临盆根据
A, model meaning and production basis
ZPD—10纸张腻滑度测定仪[无汞](以下简称腻滑仪)的各项技巧要求和检测办法,符合国际标准ISO 5627〈纸和纸板—腻滑度的测定(别克法)〉QB/T 1665〈纸和纸板腻滑仪〉等标准的各项请求与规定,是各类高腻滑纸检测所必备的仪器。
ZPD - 10 paper smoothness tester [mercury free] (hereinafter referred to as the smoothing instrument) technical requirements and test method, conforms to the international standard for the determination of ISO 5627 '- the smoothness of paper and paperboard (Bie Kefa)' QB/T 1665 'requirements for paper and paperboard smoothness tester' standards and regulations, is a variety of Gaoping slide apparatus necessary paper detection.
型号含义;

Type meaning;
Z P D——10
Z P D -- 10
进气量10毫升
Intake of 10 ml
电子式
Electronic type
腻滑
Smooth
纸张实验机
Paper testing machine
2、 用处及应用范围
Two, the use and the use scope
本腻滑仪用于高腻滑纸与纸板的测试任务,不该用于测试厚度在0.5mm以上的材料或透气度大年夜的纸或纸板,由于透过试样的空气量可形成不真实的成果。
This smoothing instrument for the Gaoping slip of paper and board test, do not apply to the testing of thickness above 0.5mm material or air permeability of paper or paperboard, because through the amount of air samples can cause false results.
3、重要技巧参数及任务条件
Three, the main technical parameter and working condition
1、任务条件
1, working conditions
(1)室温20±10℃(30分钟内温度动摇应小于0.5℃)。
(1) at 20 ± 10 ℃ (temperature fluctuation 30 minutes should be less than 0.5 ℃).
(2)任务台稳定,台面平整。
(2) the work platform stability, surface formation.
(3)任务情况应干净,枯燥,无震动,无腐化性气体。
(3) the working environment should be clean, dry, no vibration, no corrosive gas.
(4)电源电压动摇范围不该超出额外电压的10%。
(4) the power supply voltage fluctuation range should not exceed 10% of the rated voltage.
2、技巧请求.
2, the technical requirements
(1)测试范围;
(1) the scope of testing;
a.大年夜容积:1—999.9s
A. large volume: 1 - 999.9s
b.小容积:1—9999s
B. small volume: 1 - 9999s
(2)小容积:38±1mL
(2) small volume: 38 ± 1mL
(3)大年夜容积:380±3mL
(3) the large volume: 380 ± 3mL
(4)有效测试面积:10±0.05cm2
(4) the effective test area: 10 ± 0.05cm2
(5)加在试样上的压力:100±2Kpa
(5) in the sample pressure: 100 ± 2Kpa
(6)玻璃砧外径:Φ37.4±0.05mm
(6): Glass anvil diameter Φ 37.4 ± 0.05mm
(7)玻璃砧内孔:Φ11.3±0.05mm (8)橡胶垫;
(7) glass anvil hole: 11.3 ± 0.05mm (8) rubber pad;
a. 厚度:4±0.02mm
The thickness of A.: 4 ± 0.02mm
b. 硬度:40±5IRHD
The hardness of B.: 40 ± 5IRHD
c. 平行度:<0.05mm
C. parallelism: <0.05mm
d. 直径:>Φ45mm
D. diameter: > Phi 45mm
四、构造及任务道理
Four, the structure and working principle
1、构造
1, structure
(1) 容积体系:由小容积、大年夜容积、电磁阀、连接收、玻璃砧及压力传感器等构成。
(1) volume system: the small volume, large capacity, electromagnetic valve, a connecting pipe, glass anvil and pressure sensor and so on.
(2)加压机构:由重砣、支架、凸轮、杠杆、旋扭、压盖等构成。
(2) pressurizing mechanism: composed of heavy weight, bracket, cam, lever, knob, a gland.
(3)电测体系:由压力传感器、缩小年夜器、单片机及电控板构成。
(3): the electric measuring system consisting of pressure sensor, amplifier, MCU and control board.
(4)机箱及真空泵
(4) the chassis and the vacuum pump.
2、任务道理
2, work principle
腻滑仪任务道理:即在必定的真空度和实验压力下,必定量的空气经过过程试样和玻璃砧之间的接触面所需的时间,以秒为单位。试样外面愈腻滑,试样和玻璃砧外面的接触就愈慎密,经过过程必定量空气所需时间就愈长。
Smoothing apparatus principle: in the vacuum degree and the test of stress, required a certain amount of air through the sample and glass anvil contact surface of time, in seconds. The sample surface is smooth, the sample and the glass anvil surface contact more closely, the time required by a certain amount of air is long.
用大年夜容积测试,进入大年夜容积体系10mL空气,真空度由50.66Kpa降至48 Kpa所需时间即为标准腻滑度值。
With large volume test, 10mL into the air volume system, vacuum degree from 50.66Kpa to 48 Kpa time required for standard smoothness values.
关于特别腻滑的纸张,为了延长测试时间,则可应用小容积挡测试,这时候测得的时间数值平日应乘以10方是标准腻滑度,本腻滑仪经过过程软件已将标准腻滑度值法式榜样制做好,所以无需乘10即为标准腻滑值。
For particularly smooth paper, in order to shorten the test time, you can use the volume block test, numerical and measured time usually should be multiplied by 10 is the standard smoothness, the smoothing instrument by software has been the standard smoothness values make good program, so there's no need to take the 10 is the standard smooth value.
五、操作控制体系功能概述
In five, operation control system
本腻滑仪操作控制体系在操作面板上(见教意图)各操作键功能分述以下:
The smooth operation of the control system for the operating panel (see diagram) of each operating key function as follows:
1、启动 启动真空泵,实验开端,次数加1。
1, start the vacuum pump, test, and 1 times.
2、停止 停止真空泵,在实验停止或复位后,如体系在最大年夜值、最小值、均匀值、提取状况下,按一次停止键加入以上状况。
2, stop the vacuum pump, at the end of the trial or after reset, like the system in maximum, minimum, average, extraction condition, according to a stop button to exit this state.
3、复位 软件复位,体系到初始上电状况。数据打印后,假设清除保存的数据,按此键。
3, software reset system reset, the electrical state of the initial. Data printing, if you clear the saved data, press this button.
4、最大年夜值 一组数据中的最大年夜值。
4, the maximum of a set of data.
5、最小值 一组数据中的最小值。
5, the minimum value of the minimum of a set of data.
6、均匀值 一组数据中的算术均匀值。
6, the average value of a set of data the arithmetic average value.
7、大年夜容积 按此键仪器任务在大年夜容积状况。
7, the large volume press this key instrument working in large volume status.
8、小容积 按此键仪器任务在小容积状况。
8, small volume, press this key instrument working state in small volume.
9、提取 轮回显示已存数据,按一次显示一个数据。
9, the extraction cycle display stored data, according to display a data a.
10、删除 在提取状况下,删除数据。
10, removed during the extraction condition, replac data.
11、打印 打印数据。
11, the print data.
12、清零 在必定范围内清真空度,显示为零。
12, cleared in a certain range of halal empty, display zero.
本腻滑仪包含旌旗灯号收集、旌旗灯号缩小年夜、模数转换、数据打印、数据处理、输入驱动等项内容。采取高精度压力传感器,缩小年夜器采取高精度与高稳定的AD620与模数转换器,它具有接口简单、功耗低、位数高等长处。根据须要可装备串行微型汉字打印机停止数据打印。本仪用具有集成度高、稳定靠得住、
This smoothing apparatus includes signal acquisition, signal amplifier, analog to digital conversion, data printing, data processing, output drive such content. Using the high precision pressure sensor, amplifier with high precision and high stability of AD620 and analog to digital converter, it has the advantages of simple interface, low power consumption, higher number. According to the need to be equipped with serial micro Chinese characters printer to print data. The instrument has the advantages of high degree of integration, stable and reliable,
污染小等长处。
Less pollution and other advantages.
六、操作步调
Six, operation steps
1、根据试样的须要选择大年夜容积或小容积。
Selection of large volume or small volume of 1, according to the needs of the sample.
2、迁移转变旋钮晋升压盖放入试样,反转旋钮压盖降高压紧试样。
2, turn the knob ascension gland in the sample, rotating knob gland decreased compaction test.
3、按启动键次数窗显示1,真空泵任务,电磁阀同时开启对容积体系抽气,认真空度升至约53Kpa阁下,真空泵主动停止任务,电磁阀随之封闭,此时空气经过过程玻璃砧和试样接触面之间进入容积内,真空度降低,电测体系主动测出真空度由50.66Kpa降至之48Kpa之间所需的时间,既为腻滑度,以秒为单位。一个试样测试停止。
3, press the start button number 1 window display, vacuum pump, solenoid valve open at the same time the volume pumping of the system, when the vacuum degree is up to ab0ut 53Kpa, stop working automatically vacuum pump, solenoid valve closed, this time between the air through the contact glass anvil and sample surface to volume, vacuum degree, the automatic measure required between 48Kpa vacuum degree from 50.66Kpa to the time electric measuring system, both for the smoothness, in seconds. A sample test end.
4、按启动键次数窗显示2,腻滑度窗清零反复“3”实验,直至一组10个试样测试停止,可分别提取本组试样的最大年夜值,最小值,均匀值。
4, press the start button number 2 window display, smoothing window reset repeat "3" test, until a group of 10 sample test end, can be extracted from the maximum value, the minimum value of sample respectively, average value.
5、可任取10个以内的试样为一组,如8个试样为一组,5个试样为一组等,可分别提取本组试样的最大年夜值,最小值,均匀值。